3. HMP60 Temperature and Relative
Humidity Probe
3.1. General
The HMP60 Temperature and Relative Humidity probe contains a Platinum
Resistance Temperature detector (PRT) and a Vaisala INTERCAP® capacitive
relative humidity sensor.
The -L option on the model HMP60 Temperature and Relative Humidity probe
(HMP60-L) indicates that the cable length is user specified. Cable length is
specified when the sensor is ordered. Table 3.1 gives the recommended cable
length. This manual refers to the sensor as the HMP60.
2 m Height
Atop a tripod or tower via a 2 ft crossarm such as the CM202
Mast/Leg CM202 CM6
CM10
CM110 CM115 CM120
UT10
UT20
UT30
9' 11'
11'
14'
14'
19'
24'
14'
24'
37'
Note:
Add two feet to the cable length if you are mounting the enclosure on the leg base of a light-weight tripod.
3.2. Specifications
Operating Temperature: -40°C to +60°C
Probe Length: 7.1 cm (2.8 in.)
Probe Body Diameter: 1.2 cm (0.47 in.)
Filter: 0.2 μm Teflon membrane
Filter Diameter: 1.2 cm (0.47 in.)
Housing Material: chrome-coated aluminum and
chrome-coated ABS plastic
Power Consumption: 1 mA typical; 5 mA maximum
Supply Voltage: 5 to 28 Vdc
Settling Time after power is switched on: 1 second
Output Signal Range: 0 to 1 Vdc
26
Table 3-1 Recommended Cable Length