beautypg.com

Wiring – Campbell Scientific Solar1000 Station User Manual

Page 36

background image

Met One 034B Windset

CM220

CM200 Series Crossarm

FIGURE

4-2. CM200 Series Crossarm with

CM220 Right Angle Mounting Bracket

Attach the sensor cable to the six pin male connector on the 034B. Make sure
the connector is properly keyed. Finger tighten the knurled ring. Route the
sensor cable along the underside of the crossarm to the tripod/tower, and to the
instrument enclosure. Secure the cable to the crossarm and tripod/tower using
cable ties.

4.4. Wiring

Connections to Campbell Scientific dataloggers are given in Table

4.4-1. When

Short Cut for Windows software is used to create the datalogger program, the
sensor should be wired to the channels shown on the wiring diagram created
by Short Cut.




Color




Wire Label

CR800
CR5000
CR3000
CR1000


CR510
CR500
CR10(X)


21X
CR7
CR23X




CR200(X)

Red

WS

Signal

Pulse Pulse Pulse P_LL

Black

WS Signal Ref

G

Green

WD Signal

SE Analog

SE Analog

SE Analog

SE Analog

Blue

WD Volt Excite

Excitation
(VX)

Excitation Excitation Excitation

(VX)

White

WD Signal Ref

AG

Clear Shield

G

32

Table 4.4-1 Connections to Campbell Scientific Dataloggers