beautypg.com

Installation, 1 siting – Campbell Scientific Solar1000 Station User Manual

Page 38

background image

TE525 Tipping Bucket Rain Gage

Signal Output:

Momentary switch closure activated by tipping bucket mechanism.

Switch closure is approximately 135 ms.

Calibration/Cleaning Frequency:

Sensor is factory calibrated and should not require field calibration.

Debris filters, funnel, and bucket reservoirs should be kept clean. Section

6 describes field calibration check and factory calibration.

Environmental Limits:

Temperature: 0° to +50°C

Humidity: 0 to 100%

Physical Data:

Diameter: 6.25 in. overall

Height

TE525 9.5

in.

TE525WS

12

in.

TE525MM

12

in.

Weight: 2.5 pounds

Funnel: Gold anodized spun aluminum knife edge collector ring and

funnel assembly.

Funnel Collector Diameter:

TE525 6.064

in.

TE525WS

8

in.

TE525MM

9.664

in.

Resolution: 1 tip

Mounting: Side bracket with clamps for pole or mast mounting

Material: Aluminum

Cable: 2-conductor, shielded cable, length must be specified when

ordering.

The black outer jacket of the cable is Santoprene

®

rubber. This

compound was chosen for its resistance to temperature extremes,

moisture, and UV degradation. However, this jacket will

support combustion in air. It is rated as slow burning when

tested according to U.L. 94 H.B. and will pass FMVSS302.

Local fire codes may preclude its use inside buildings.

NOTE

5.3. Installation

The 260-953 Alter-Type Wind Screen’s siting information and

installation procedure are provided in our 260-953 manual.

NOTE

5.3.1 Siting

The rain gage should be mounted in a relatively level spot which is

representative of the surrounding area. The lip of the funnel should be

horizontal and at least 30 cm. above the ground. It should be high enough to

be above the average snow depth. The ground surface around the rain gage

should be natural vegetation or gravel. It should not be paved.

34