NL200/201 Network Link Interface
However, an allowed neighbors list can be useful in restricting
communication paths.
•
On the Network Services tab:
o Make note of the PakBus\TCP Server Port. (The default
PakBus/TCP Server Port is 6785. Unless firewall issues exist, it is
not necessary to change the port from its default value.)
CS I/O PakBus® Router
•
Connect to the NL200/201 in DevConfig (see Section 6, Configuring the
NL200/201).
•
On the NL200 tab:
o Set Bridge Mode to disable.
•
On the CS I/O tab:
o Set Configuration to PakBus.
o Set SDC address. (Note that if multiple peripherals are connected to
a datalogger’s CS I/O port, each must have a unique SDC address.)
o Set Beacon Interval and Verify Interval as described above. Often
the default values can be used.
•
On the Network Services tab:
o Make note of the PakBus\TCP Server Port. (The default
PakBus/TCP Server Port is 6785. Unless firewall issues exist, it is
not necessary to change the port from its default value.)
7.1.3 LoggerNet Setup
•
In the LoggerNet Setup screen, press
Add Root and choose IPPort. Input
the NL200/201’s IP address and port number. The IP address and port
number are input on the same line separated by a colon.
•
Add a PakBus® Port (PakBusPort).
•
Add a PakBus® Router (pbRouter). Input the PakBus address of the
NL200/201. The NL200/201’s default PakBus address is 678.
•
Add the datalogger and input the PakBus® address of the datalogger.
•
Press
Apply to save the changes.