5. Specifications
General
177 g (6.3 oz)
16 x 6.73 x 2.54 cm (6.3 x 2.65 x 1 in)
FIGURE 5-1. NL200/201 dimensions in inches
Power Input
NL201: CS I/O or barrel connector jack; not powered over USB
NL200: Barrel connector jack; not powered over CS I/O or USB
Power Requirements
7 to 20 Vdc
50 mA active, 2 mA standby @ 13 Vdc
Standby power is when the IPNetPower instruction has been used
to turn off power to the Ethernet. See the CRBasic help for an
example of using the IPNetPower instruction. Note that the
IPNetPower instruction is only applicable when the NL200/201 is
configured with Bridge Mode Enabled.
Operating Temperature
Standard: –25 to +50 °C
Extended: –55 to +85 °C
Configuration
DevConfig over USB or Ethernet
Telnet console over Ethernet
Terminal menu over RS-232
CS I/O Port
SDC 7, 8, 10, 11 (does not support ME)
9600 bps to 460.8 kbps
RS-232 Port
DTE
1200 bps to 115.2 kbps