Appendix A. EC150 Settings

3. The option of a third barometer choice is also available but is rarely

used. A user-supplied barometer option can also be programmed in

the EC100 electronics. This setting determines which pressure sensor

will be used to measure the barometric pressure.

User-supplied Barometer:

When a user supplies a barometer, the setting should be changed to

User Supplied and the appropriate values for gain and offset must be

entered.

Sampling Frequency:

The enhanced barometer is sampled at 1 Hz. If the user supplies an external

pressure sensor, it is sampled at 1 Hz. The on-board pressure sensor is

measured at 10 Hz. In all cases, the pressure sensor measurement is not

synchronized to the CO

2

and H

2

O measurements.

The pressure sensor also allows the setting

None for the Pressure Sensor.

This mode is intended for troubleshooting only. The EC100 will use a fixed

value for pressure.

The

Pressure Sensor setting is stored in non-volatile memory in the EC150

head.

A.2.10.1 Pressure Gain

This setting is not used unless the

Pressure Sensor is set to User Supplied.

Then this setting gives the gain factor (kPa/V) used to convert measured

voltage to pressure. If the

Pressure Sensor is set to EC100 Basic or EC100

Enhanced, this setting is not used.
The

Pressure Gain setting is stored in non-volatile memory of the EC100.

A.2.10.2 Pressure Offset

This setting is not used unless the

Pressure Sensor is set to User Supplied.

Then this setting gives the offset (kPa) used to convert measured voltage to

pressure. If the

Pressure Sensor is set to EC100 Basic or EC100 Enhanced,

this setting is not used.

The

Pressure Offset setting is stored in the EC100 electronics.

A.2.10.3 Fixed Pressure Value

If the

Pressure Sensor setting is None, the EC150 will use the value of this

setting for the barometric pressure. This mode is intended for troubleshooting

only. In normal operation this setting is not used.

The

Fixed Pressure Value setting is stored in the EC100 electronics.

A.2.11 Pressure Differential Enable

This setting should remain disabled. It is used only for closed-path analyzers.

The

Pressure Differential Enable setting is stored in non-volatile memory in

the EC150 head.