4 find, 1 date/time, 2 events – Videoswitch Vi-M series User Manual
Page 24: 4 alarm, 5 system, 6 critical, Find, Date/time, Events, Alarm
![background image](/manuals/409951/24/background.png)
Digital Recorder
4 Find
• On a mini-keypad, Find is accessed by pressing SEL to enter the root menu, then
using up and down to select the required row, followed by SEL
• On a standard keypad, Find may be accessed directly by pressing the FIND key.
Press Find key again to switch between different find options.
4.1 Date/Time
• Use
left and right to move the cursor
• Use
up and down to scroll the digits
• A search will take place each time you change a digit and the image will be
displayed
• Press
DEFAULT for the latest available image
• Press
DEFAULT again for the earliest available image
4.2 Events
There are a number of event logs which store potentially large numbers of events. As you
scroll though these logs, the corresponding image is recalled and displayed on the screen.
1.1.4 Alarm
This log records alarm and activity events. It also logs Tag events which are manually
generated events.
1.1.5 System
This log record system events such as Ethernet access, log-ins and other normal system
activities.
1.1.6 Critical
This log record critical alerts which are error events. An example is a hard drive failure.
Events that have not been acknowledged are shown in red.
• Select the row using up, down, left and right
• Press
SEL to cancel event
• If critical alert condition persists, another alert will be raised
• If there are a lot of critical alerts, they can all be cleared at once in the Alarms
menu
18