Status message format, Evc/epc controller, With sae j1939 interface – High Country Tek epc, Electronic Pump Controller - A Multi-Function SAE J1939 Compatible Module User Manual
Page 40
023-00354-Rev1.6
evc/epc User Manual
40
Copyright © High Country Tek, Inc.
– 2013
evc/epc Controller
With SAE J1939 Interface
Status Message Format
Transmission Cycle Time
100mS
Data Length
8
Data Page
0
PDU Format
255
PDU Specific
Module ID + 128
Priority
3
Parameter Group Number
65409 Through 65535
(FF81 Through FFFF)
Status Message
Start Position
Length
Parameter Name
1
1 Byte
Always = 1 (Status)
2.1
1 bit
Command Input Error
2.2
1 bit
Reference Voltage Error
2.3
1 bit
Pulse Input LOS
2.4
1 bit
Power Supply High
2.5
1 bit
Power Supply Low
2.6
1 bit
Coil A Msg Timeout
2.7
1 bit
Coil B Msg Timeout
2.8
1 bit
RPM Msg Timeout
3.1
1 bit
not used
3.2
1 bit
Reverse Cycle Active
3.3
1 bit
Digital Input 1 State
3.4
1 bit
Digital Input 2 State
3.5
1 bit
Coil A Short
3.6
1 bit
Coil A Open
3.7
1 bit
Coil B Short
3.8
1 bit
Coil B Open
4.1
1 bit
Process A Ramping
4.2
1 bit
Process B Ramping
4.3
1 bit
Command Input Not Centered
4.4
1 bit
Reverse Cycle Retry Timeout
4.5
1 bit
System in Startup Mode
4.6
1 bit
System in Shutdown Mode
4.7
1 bit
not used
4.8
1 bit
not used
5-6
2 Bytes
Coil A Current (mA)
7-8
2 Bytes
Coil B Current (mA)