Evc/epc gui overview, File, Evc/epc controller – High Country Tek epc, Electronic Pump Controller - A Multi-Function SAE J1939 Compatible Module User Manual
Page 11: With sae j1939 interface

023-00354-Rev1.6
evc/epc User Manual
11
Copyright © High Country Tek, Inc.
– 2013
evc/epc Controller
With SAE J1939 Interface
evc/epc GUI Overview
File
All changes made through the GUI are temporary until saved permanently
.
Permanently save settings to unit:
Save the settings to the unit
’s EEPROM (permanent memory).
Permanently save settings to unit & file (.dat)
:
Permanently save the settings to the unit
’s EEPROM and to a
data file that may be uploaded into any evc/epc controllers later.
Settings will be lost if not permanently saved before power cycle.
To reset the unit with a power cycle, you must remove both the USB cable and DC power from the unit.
Restore unit to last permanent settings saved:
Reload settings stored in the EEPROM. This will undo all
changes made since the last Permanent Save.
Restore unit settings from data file (.dat):
Load the data file from the PC to the evc/epc.
Restore unit from v1.03 data file:
Load the previous version data file from the PC to the evc/epc.