AMETEK 2120 PLC Interface Module User Manual
Page 56
52
Installation and Programming Manual
Appendix B: Function Summary
Chart B-2 Resolver-Specifi c Function Summary
Chart B-1 General Function
The following chart contains LDT Specifi c function summaries: LDT Input V1 and L1 Functions
The following chart contains resolver-specifi c function summaries: Resolver Input R1 Functions
Function Number
Function Name
Description
403
Relay Override
This function is used to temporarily allow the operator
to readjust machine position once it has exceeded a
programmed end limit.
590
Software Version
This function displays the software version of your
monitor.
Function Number
Function Name
Description
300
Scale Factor
This function is used to program the resolver’s scale
factor.
301
Turns Counting
This function defi nes the number of revolutions the
resolver must rotate before the scale factor is reached.
302
Position Offset
This function is used to synchronize displayed position
with actual machine position.
305
Display Power Up
This function is used to determine what will appear on
the display on Power Up.
306
Fault Pulse Time
Consult factory if using LDT other than Gemco.
307
Resolver Reset-to-Preset
This function is used to set the Resolver’s Reset-to-
Preset value.
308
Select Wrap Around
This function is used in conjuction with 301 (Turns
Counting) and allows for the display to roll over after
it’s maximum count.
Function Number
Function Name
Description
300
Wire Speed
This function is used to program the wire speed of the
installed LDT.
301
Count Direction
This function is used to change the direction the Inter-
face Module counts as the LDT’s magnet travels along
the guide rail.
302
Position Offset
This function is used to synchronize displayed position
with actual machine position.
306
Fault Pulse Time
This function is used to program the pulse time of the
fault signal sent by the LDT when it detects an error.
307
LDT Output Type
This function is used to confi gure the L1 input board
for use with a specifi ed LDT output.
311
LDT L1 Input Reset-to-Preset
This function is used to set the LDT L1 Reset-to-Preset
value.
Chart B-3 LDT Specifi c Function Summary