4. Press START/STOP button to clear the
memory. Three dashes (– – –) appear on the
display.
5. Let the oven cycle on and off at least two times.
6. Press MAX/MIN again to read the highest
temperature the oven had reached (
MAX).
7. Press MAX/MIN again to read the lowest
temperature the oven had reached (
MIN).
Note:
Clean the thermometer probe before each use.
Note for Induction Cooktops:
Sometimes, the induction
cooktop magnetic field may interfere with digital thermometers.
If there is interference, briefly turn off the induction cooktop to
get a digital thermometer reading or use a dial thermometer.
Important: DO NOT LEAVE THERMOMETER CASE IN
HOT OVEN. CASE IS NOT HEAT RESISTANT.
Tip:
Meat should be allowed to “rest” for 10 to 15 minutes after
it is removed from oven. This allows time for the meat’s internal
temperature to stabilize and the juices to redistribute. This will
result in a roast that is both juicier and easier to carve.
Specifications
Temperature Alert: 14 to 392°F/-10 to +200°C;
°F/°C selectable
Power:
1 DC 1.5V AAA
Alkaline battery
Timer:
Counts up/down 24 hours
Clock:
12/24 hours selectable
Precautions
•
Always wear heat resistant gloves to touch the
stainless steel probe sensor or wire during or just
after cooking.
Do not touch with bare hands.
•
Keep the stainless steel probe sensor and wire away
from children.
•
Clean the sensor probe and dry thoroughly after
use.
•
Do not clean the unit with abrasive or corrosive
compound, which may scratch the plastic parts and
corrode the electronic circuits.
•
Do not subject the units to excessive force shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and distorted parts.
•
Do not tamper with the unit’s internal component.
Doing so will invalidated the warranty on the unit
and may cause unnecessary damaged battery and
distorted parts.
•
Do not subject the units to excessive exposure to
direct sunlight.
The unit is not waterproof. Do
not immerse it into water or expose to heavy rain.
•
Do not expose the plug of the stainless steel probe
or the plug in holes of the unit to water or any
liquid, which will result in a bad connection and
faulty readings.
•
To avoid deformation, do not place the unit in
extreme temperatures. Never burn the steel probe
directly over the fire. Do not use the stainless
steel probe sensor when the temperature is above
392°F/200°C. The sensor wire is heat safe to
600°F/316°C.
•
Do not use the probe in microwave oven.
•
Always read the users manual thoroughly before