ARI Armaturen ARI-PACO 0,85kN EN User Manual
Page 14

Page 14
0040506000 1811
Operating and installation instructions
Electric thrust actuator ARI-PACO 0,85 kN
5.4.3.1 ARI-PACO 0,85 D
- Connect the ground line of the connection lead to connector 1 of the connection strip of
the linear actuators
- Connect the impulse lead for the extended thrust rod on connector 2 of the connection
strip terminal.
- Connect the impulse lead for the retracted thrust rod on connector 3 of the connection
strip terminal.
-
Ρeplace housing carefully from above and mount with two recessed screws on the linear
actuator.
- Set sliding switch on the housing to automatic operation.
- Connect the supply lines to the mains and move the linear actuator into each of the end
positions in order to test if the end position switches shut off, and if the direction of
movement of the linear actuators is as desired.
- In case the direction of movement is opposite to that which is desired, the impulse cables
for the extending and the retracting thrust rod should be exchanged.
5.4.3.2 ARI-PACO 0,85 Y
- Connect the 24 V AC - voltage supply an connector 1 and V terminals (connector 1 = 0 V)
- Connect the control with a continuous signal of 0(2)...10 V on connector 1 and Y
terminals. (connector 1= 0 V)
- Connect the actuating output signal 0...10 V on connector 1 and A terminals (connector 1=
0 V).
- For priority switching (frost protection limitation) for retracted thrust rod on connector
1 and 2 terminals.
- For priority switching (frost protection limitation) for extended thrust rod on
connector 1 and 3 terminals.
- Replace housing carefully from above and mount with two recessed screws on the linear
actuator.
- Set sliding switch on the housing to automatic operation.
- Connect leads to mains and actuating signal
Carry out an initialization run (refer to 6.2.1 )