Vaisala WMT52 User Manual
Page 86

User’s Guide ______________________________________________________________________
84 ___________________________________________________________________M210925EN-B
Command format: $--WIQ,MWV*hh
The response format:
$WIMWV,x.x,R,y.y,M,A*hh
The checksum to be typed in the query depends on the device identifier
characters. The correct checksum can be asked from WMT52 by typing
any three characters after the $--WIQ,MWV command.
where
$
=
Start of the message
--
=
Device identifier of the requester
WI
=
Device type identifier (WI = weather instrument)
Q
=
Defines the message as Query
MWV
=
Wind speed and direction query command
*
=
Checksum delimiter
hh
=
Two-character checksum for the query command.
=
Command terminator
where
$
=
Start of the message
WI
=
Talker identifier (WI = weather instrument)
MWV
=
Wind speed and direction response identifier
x.x
=
Wind direction value
1
1. Wind direction is given in relation to the devices north-south axis. An
offset value to the measured direction can be set, see section Chapter 8,
section Wind Sensor.
R
=
Wind direction unit (R = relative)
y.y
=
Wind speed value
M
=
Wind speed unit (m/s)
A
=
Data status: A = valid, V = Invalid
*
=
Checksum delimiter
hh
=
Two-character checksum for the response
=
Response terminator