Start concurrent measurement with crc (acc) – Vaisala WMT52 User Manual
Page 79

Chapter 7 __________________________________________________ Getting the Data Messages
VAISALA_______________________________________________________________________ 77
The measured data is not sent automatically and it should be requested
with separate Send data command aD. See
Command format: aCx!
The response:
atttnn
Start Concurrent Measurement with
CRC (aCC)
Command format: aCCx!
where
a
=
Device address
C
=
Start concurrent measurement command
x
=
The desired measurement
1 = Wind
5 = Supervisor
If x is left out, the query refers to combined data
message in which the user can request data from
several sensors with just one command. See the
examples below.
!
=
Command terminator
where
a
=
Device address
ttt
=
The measurement completing time in seconds
nn
=
The number of the measured parameters available
(maximum number is 20)
=
Response terminator
NOTE
For changing the message parameters, units and other settings, see
Chapter 8, Sensor and Data Message Settings, on page 95
.