Communication Protocol

Set the communication protocol to ASCII polled (with or without CRC)
or NMEA query. When using NMEA query, the wind message should
be set to XDR (aWU,N=T).

ASCII, Polled

WMT52s on the bus shall be assigned with different addresses. (for
example: aXU,A=0,1,2, ... ).

Example (a bus with three WMT52s):

WMT52 #1 communication settings:
0XU,A=0,M=P,C=3,I=0,B=19200,D=8,P=N,S=1,L=25

WMT52 #2 communication settings:
1XU,A=1,M=P,C=3,I=0,B=19200,D=8,P=N,S=1,L=25

WMT52 #3 communication settings:
2XU,A=2,M=P,C=3,I=0,B=19200,D=8,P=N,S=1,L=25

Example (composite data message queries to the sensors 1 and 3 are
assigned as follows):

0R0

1R0

2R0

NOTE

No matter which communication protocol, ASCII polled or NMEA
query is chosen, the error messaging parameter of the supervisor
message must be disactivated with aSU,S=N for each WMT52 on the
bus in order to prevent the units responding to the commands not
assigned to them.