Continuous measurement with crc (arc), Start verification command (av) – Vaisala WMT52 User Manual
Page 83
Chapter 7 __________________________________________________ Getting the Data Messages
VAISALA_______________________________________________________________________ 81
a+
Examples (device address 0):
0R1!0+323+331+351+0.0+0.4+3.0
0R5!0+20.3+12.0+12.2+3.530
0R!0+178+288+001+15.5+27.4+38.5+23.9+35.0+1002.1+0.00+0+
0.0+23.8
Continuous Measurement with CRC
(aRC)
Command format: aRCx!
Has the same function as the Continuous measurement command aR
but a three-character CRC is added to the response data strings before
Example (device address 0):
0RC3!0+0.04+10+14.8+0.0+0+0.0INy
Start Verification Command (aV)
This command is used to query self diagnostic data from the device.
However, the command is not implemented in WMT52. The self-
diagnostic data can be requested with aM5 command.
where
a
=
Device address
fields>
=
The measured parameters in selected units, separated
with '+' marks (or '-' marks in case of negative
parameter values). The maximum number of
parameters to be measured with one reqeust is 15.
=
Response terminator