background image

Assembly

900-0123-01-00 Rev B

21

Mounting FLEXmax Charge Controller

The GSLC enclosure accommodates up to two FLEXmax charge controllers and a HUB
Communications Manager.

NOTE: The following instructions are for the FLEXmax 60 or FLEXmax 80 only. The FLEXmax Extreme
charge controller connects directly to the wall and does not need additional brackets.

Figure 21

Mounting the Charge Controller to the GSLC Enclosure

2.

Align the charge controller with
the center hole on each bracket
and secure with the hardware
provided with the brackets.

To mount the FLEXmax Charge
controller to the side of the GSLC
enclosure:

1.

Align the brackets to the
mounting holes and secure the
brackets to the sides of the
enclosure with the hardware
provided with the brackets.

3.

Secure to the bottom bracket.

NOTE: This illustration shows only brackets for a

single charge controller. Dual charge
controller brackets are also available and
install the same as the single bracket.

Dual Charge Controller
Bracket