OmniSwitch 6800 Series switches can be monitored and managed via the console port using Command
Line Interface (CLI) commands. The switches can also be monitored and managed via the Ethernet ports
using CLI commands, WebView, SNMP, and OmniVista.
The section below provides some examples of useful hardware-related monitoring CLI commands. Refer
to the OmniSwitch CLI Reference Guide for detailed information on all management and monitoring
commands used with the OmniSwitch 6800 Series switch. For comprehensive information on managing
and monitoring stacked configurations, refer to
Chapter 3, “Managing OmniSwitch 6800 Series Stacks.”
Checking Overall Chassis Status
To check the overall status of a chassis, including the chassis type, and current administrative and opera-
tional status, use the
show chassis
command. For example:
-> show chassis
Chassis 1
Model Name: OS6800-48,
Description: 10/100/1000,
Part Number: 902274-10,
Hardware Revision: 005,
Serial Number: 439L0024,
Manufacture Date: SEP 22 2004,
Admin Status: POWER ON,
Operational Status: UP,
Number Of Resets: 1
When the show chassis command is issued for a stacked configuration, status information for all switches
in the stack displays. For a complete list of output definitions for this command, refer to the OmniSwitch
CLI Reference Guide.
Checking Temperature Status
To check chassis temperature status, including the current temperature and configured threshold values,
use the
show temperature
command. For example:
-> show temperature
Temperature for chassis 1
Hardware Board Temperature (deg C) = 38,
Hardware Cpu Temperature (deg C) = N/A,
Temperature Upper Threshold Range (deg C) = 30 to 72,
Temperature Upper Threshold (deg C) = 57,
Temperature Range = UNDER THRESHOLD,
Temperature Danger Threshold (deg C) = 72
When the show temperature command is issued for a stacked configuration, status information for all
switches in the stack displays. For a complete list of output definitions for this command, refer to the