Vantage Pro2 Troubleshooting Guide

35

Troubleshooting Reception Problems
While we have tested the Wireless Vantage Pro2 radio extensively, each site and each
installation presents its own issues and challenges. Obstructions, particularly metallic
ones, often cut down your station’s reception distance. Be sure to test reception
between the console and ISS, in the locations you intend to install them, before perma-
nently mounting your ISS or other transmitter(s).
The console’s reception status displays at the lower right corner of the screen.

Temperature

Outside temperature sen-

sor reading seems too high

Check to see if ISS is near mechanical or radiant heat source.

Check calibration number and adjust if necessary. ISS or temp

sensor may need to be relocated. See ISS or other transmitter

manual.

Inside temperature sensor

reading seems too high

Move the console out of direct sunlight. Make sure that the con-

sole or sensor is not in contact with an exterior wall that heats

up in sunlight or when outside temperature rises. Make sure the

console or sensor is not near a heater or other internal heat

source (lamps, appliances, etc.). Also make sure the console

backlight is not on. Check calibration number and adjust if nec-

essary.

Outside temperature

seems too low

Check calibration number and adjust if necessary. Sprinklers

may be hitting the ISS radiation shield. Relocate. See ISS man-

ual.

Inside temperature sensor

reading seems too low

Make sure the console or other temperature sensor is not in

contact with an exterior wall that cools down when outside tem-

perature drops. Make sure the console or other temperature

sensor is not near an air conditioning vent. Check calibration

number and adjust if necessary.

Wind Direction

Wind direction reading is

dashed out

Wireless model - check reception. See Reception Prob-

lems below.

Cabled model - cable may be faulty.

If these steps do not reveal the problem, the anemometer may

be faulty. Call technical support.

Wind direction always says

north

Usually a problem in the ISS, either with the transmitter or ane-

mometer cable. See the ISS manual for troubleshooting infor-

mation.

Chill

Wind chill reading seems

too high or too low

Check calibration numbers for temperature. Wind chill depends

on temperature and wind speed. Make sure they’re working.

Heat

Heat Index reading seems

too high or too low

Check calibration numbers for temperature. The heat index de-

pends on temperature and outside humidity. Make sure the sen-

sors are working.

Rain

No rain readings

Make sure cable-tie is removed from inside the rain collector.

See the ISS manual.

UV/Solar

Readings are too high

Can be caused by high thin cirrus clouds.

Time

Incorrect times for sunrise

and sunset

Check your latitude, longitude, time zone, and daylight savings

time settings. Sunrise and sunset times are calculated from the

console using all of these settings.

T

ABLE

4-1: T

ROUBLESHOOTING

G

UIDE

Problem

Solution