2. WE-8 CONTROL HAS NO VISIBLE DISPLAY (Q AND X-VOLTAGE MODELS)

Is there

Voltage (120

Volts) into

and out of the

3.15 Amp

fuse?

NO

YES

NO

Reset and return (either by pulling or by
twisting and pulling) the E-stop switch.
If, after resetting and returning, there is
still no voltage, replace the E-stop
switch.

Check the L2 (blue) and L1 (brown) wires
between the E-stop switch and the power
connector on the main board. Repair or
replace the wires as needed.

Check the cable between the main board
and the keypad for any loose or broken
connections. repair or replace the cable
as needed.

If the cable is intact, please contact
Alliance Laundry Systems’ customer
service department before replacing
the main board, keypad or cable between
the main board and keypad.

Is there

voltage (120

Volts) into and

out of both sides of

the e-stop

switch?

Is there

voltage (220

Volts) between the

L2 (blue) and L1 (brown)

wires going into the

power connector

on the main

board?

Is the

125 mA fuse

above the power

connector on the

main board blown?
An ohms test is the

recommended

check for

the fuse.

YES

NO

YES

NO

2

1

3

4

YES

5

6

NO

Replace the 3.15 Amp fuse.

Replace the 125 mA fuse.

YES

CFD4S

The WE-8 control has
no visible display.

Is

the main

power circuit

breaker

on?

Turn on the main power
circuit breaker.

NO

YES

Is

there

voltage

(200-240 Volts)

coming out of the
main power block

between wires

L2 (blue) and

L1 (brown)?

Check the main power circuit
breaker and power to the machine.