Section 3 Troubleshooting

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

During each step, test for voltage (220 Volts) between each respective supply terminal and the common
terminal on the supply terminal board. Terminal 14 is the common terminal for the pumps.

The supply terminal board should be wired as shown in Figure 2.

Figure 2

CFS8N

Pump

1

Pump

2

Pump

3

Pump

4

Pump

5

Pump

6

Supply

Relay

1

1

2

Supply

Relay

2

3

4

Supply

Relay

3

5

6

Supply

Relay

4

7

8

9

10

Supply

Relay

5

Supply

Relay

6

11 12

13* 14**

ELECTRICAL CONNECTION OF THE LIQUID SUPPLY PUMPS

* L1 (110 VAC) wire or terminal for remote liquid supply connection.
** L2 common wire (110 VAC) or terminal for remote liquid supply connection.