Service procedures, Top cover removal and replacement, Keypad removal and installation – Alliance Laundry Systems HX User Manual
Page 67: Section 4 – service procedures, Warning
9001900
65
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electrical power to the washer-extractor before servicing it.
• Close the gas shut-off valve to the washer-extractor (when applicable) before servicing it.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W461R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 4
Service Procedures
19. TOP COVER REMOVAL AND
REPLACEMENT
Refer to Figure 3.
REMOVAL
a. Turn off power to the machine.
b. Using a 10 mm socket wrench, remove the
screws that attach the top cover to the machine.
c. Lift the top cover off of the machine.
REPLACEMENT
a. Replace the top cover onto the machine.
b. Using a 10 mm socket wrench, replace the
screws that attach the top cover to the machine.
20. KEYPAD REMOVAL AND INSTALLATION
Refer to Figure 4.
REMOVAL
a. Turn off power to the machine.
b. Remove the top cover. Refer to Paragraph 19.
c. Disconnect the ribbon cables from the keypad.
d. Using a 5.5mm nut driver, remove the nuts that
attach the keypad to the control panel.
e. Remove the keypad.
INSTALLATION
a. Position the keypad.
b. Using a 5.5 mm nut driver, replace the nuts that
attach the keypad to the control panel.
c. Reconnect the ribbon cables to the keypad.
d. Replace the top cover. Refer to Paragraph 19.
e. Turn on power to the machine.
f. Test the keypad’s buttons by pressing each one
and checking for a single beep.
Figure 3
CFD6S
Top
Cover
Figure 4
CFD9S
Control
Panel
Keypad
Ribbon
Cables