beautypg.com

Door lock switch analysis: display shows, Door error – Alliance Laundry Systems HX User Manual

Page 28

background image

26

9001900

Section 3 Troubleshooting

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

5. DOOR LOCK SWITCH ANALYSIS: DISPLAY SHOWS “DOOR ERROR”

CFD1993S

1

The display reads “door error”.

Check

the wiring from the

door terminal on the main

board to the molex plug

(75-165 models only)

and from the molex plug to
the door lock switches and

solenoid. Is the wiring intact

and properly

connected?

YES

2

3

Repair/replace the wiring as
needed.

NO

Is

there voltage (70

Volts AC) between

the white/brown and

white/orange wires

on the top

switch?

Replace the top switch.

YES

Is

there voltage (70

Volts AC) between

the black and red

wires wires on the

solenoid?

NO

Replace the solenoid.

YES

Is

there voltage (70

Volts AC) between the

black and red

terminals on the main

board's door

terminal?

NO

Replace the main board.

NO

YES

This manual is related to the following products: