8. NO OUTPUT VOLTAGE TO COMPONENTS
Figure 1
Component
Voltage Reading Points
Voltage Reading
Water
Flush A
Clear wire to Blue wire
220 Volts AC
Hard Fill
White/Black wire to Blue wire
220 Volts AC
Hot Fill
Red wire to Blue wire
220 Volts AC
Cold Fill
Gray wire to Blue wire
220 Volts AC
Flush C
White wire to Blue wire
220 Volts AC
Flush B
Purple wire to Blue wire
220 Volts AC
Drain
Drain Motor Fan
Clear wire to Blue wire
220 Volts AC
Drive Fan
Clear wire to Blue wire
220 Volts AC
Door
Door Latch Switch Orange/White wire to White/Brown wire
5 Volts DC
Door Lock Switch
Orange/White wire to White/Black wire
5 Volts DC
Door Solenoid
Black wire to Red or White wire
70 Volts AC
Tilt
Tilt
White/Purple wire to White/Orange wire
5 Volts DC
Soap
S4
White/Orange wire to Black wire
24 Volts DC
S5
Red/Black wire to Black wire
24 Volts DC
S6
Yellow/Red wire to Black wire
24 Volts DC
S7
White/Brown wire to Black wire
24 Volts DC
S8
Red/Gray wire to Black wire
24 Volts DC
S9
White/Red wire to Black wire
24 Volts DC
Component Voltage/Reading Points Chart
CFD2000S
Figure 1
1
Is there
voltage (refer to
Figure 1) on the main
board terminals that
the wires going to the
component are
connected
to?
2
Replace the
main board.
NO
Repair/replace the wiring as
needed.
YES
NO
Is
there
voltage (refer to
Figure 1) on the
wires on the input
side of the
components?
Repair/replace the component
as needed.
YES