beautypg.com

Drain valve, Door gasket removal and replacement, Warning – Alliance Laundry Systems HX User Manual

Page 76

background image

74

9001900

Section 4 Service Procedures

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electrical power to the washer-extractor before servicing it.
• Close the gas shut-off valve to the washer-extractor (when applicable) before servicing it.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the washer-extractor is properly grounded.

W461R1

WARNING

28. DRAIN VALVE

Refer to Figure 13.
If the washer-extractor doesn’t drain within 30
seconds, perform the following check:
a. Turn off power to the machine.

b. Remove any panels necessary to access the

drain valve and drain plumbing.

c. Check for a clog in the drain line.

d. Verify that the drain valve is opening.

(1) The drain valve is normally open (i.e., it

requires voltage to close).

(2) When power is removed from the machine,

the drain valve should open.

e. If the drain is not opening, check for the

following:

(1) Check the motor winding for continuity, a

short circuit or an abnormal drop in
voltage. Replace the drain valve as needed
(consult the machine’s parts manual for
drain valve part numbers).

(2) Check that the shaft and rotor of the drain

motor turns freely.

(3) Check that the internal drain valve is

closing and does not bind. A clog within
the drain valve may be preventing the drain
valve from closing. Replace the drain valve
as needed (consult the machine’s parts
manual for drain valve part numbers).

f. Check the wire continuity from the drain valve

to the plug on the computer board.

g. Re-install any panels removed in Step b.

29. DOOR GASKET REMOVAL AND

REPLACEMENT
Refer to Figure 14.

REMOVAL
a. Turn power off to the machine.

b. Remove the door glass (with the door gasket

attached) from the door.

c. Remove the door gasket from the door glass.

REPLACEMENT
a. Install the door gasket onto the door glass.

b. Insert the door glass (with the door gasket

attached) into the door.

Figure 13

Figure 14

CFD16S

Drain
Valve

CFD17S

Door

Gasket