13. MACHINE DID NOT FILL ALARM ANALYSIS

CFD1989S

1

Is there water coming in
through the water supply
lines?

IS

there voltage

(220 Volts) at the
respective water

valve that should

be turning

on?

Check the main water valve
shut-offs, inside of the
water hoses and in-line
strainers.

NO

YES

Replace the water valve.

YES

Is

there

continuity

between the wire

from the main

board to the

water valve?

2

NO

Replace the main board.

YES

Is

there voltage (220

Volts) between the

drain wires on the main

board?

For example, for the

cold fill valve, is there

voltage between the

gray (cold fill) and blue

(common) wire?

3

4

NO

Replace the water valve.

YES

Is

the water plug

harness

connector on the

main board

intact?

NO

Replace the main board.

Replace the water valve
wiring harness.

YES

NO