Section 3 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3. NO FILL ANALYSIS
CFD18S
NO
NO
Check the wiring between the
main board and the water valve
that has been programmed to
turn on. Repair or replace the
wiring as needed.
Note: There may be a modular
connector between the wire
and the main board.
2
1
3
YES
Replace or repair the
mechanical parts of the valve
with a repair kit if available. If
a repair kit isn’t available,
replace the entire valve.
YES
NO
Assuming that all
checks were done
correctly, replace the
main board or contact
Alliance Laundry
Systems’ customer
service department to
verify that all checks
have been done
correctly.
Is
there water
coming in through
the water supply
lines?
Check the main water valve
shut-offs to make sure that
they are turned on. Check
inside of the water hoses and
in-line screens for any
blockages.
NO
YES
YES
Is there voltage
(220 Volts) between the
two wires of the
water valve that
has been
programmed to turn
on?
Is
there voltage
(220 Volts) between
the wire from the main
board harness on the water
valve that has been programmed
to turn on?
The red wire is the hot fill,
the gray wire is the cold fill
and the blue wire
is the neutral.
Is there
magnetism within
the center
walls of the
valve
solenoid?
Replace the valve’s solenoid if
available. If the solenoid isn’t
available, replace the entire
valve.