Section 3 Troubleshooting

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

3. NO FILL ANALYSIS

CFD18S

NO

NO

Check the wiring between the
main board and the water valve
that has been programmed to
turn on. Repair or replace the
wiring as needed.

Note: There may be a modular
connector between the wire
and the main board.

2

1

3

YES

Replace or repair the
mechanical parts of the valve
with a repair kit if available. If
a repair kit isn’t available,
replace the entire valve.

YES

NO

Assuming that all
checks were done
correctly, replace the
main board or contact
Alliance Laundry
Systems’ customer
service department to
verify that all checks
have been done
correctly.

Is

there water

coming in through

the water supply

lines?

Check the main water valve
shut-offs to make sure that
they are turned on. Check
inside of the water hoses and
in-line screens for any
blockages.

NO

YES

YES

Is there voltage

(220 Volts) between the

two wires of the
water valve that

has been

programmed to turn

on?

Is

there voltage

(220 Volts) between

the wire from the main

board harness on the water

valve that has been programmed

to turn on?

The red wire is the hot fill,

the gray wire is the cold fill

and the blue wire

is the neutral.

Is there

magnetism within

the center

walls of the

valve

solenoid?

Replace the valve’s solenoid if
available. If the solenoid isn’t
available, replace the entire
valve.