beautypg.com

Application configuration (cont.), Step, Configuration settings – Ag Leader InSight Raven Serial, NL Mark V, SP6 User Manual

Page 4: Product setup

background image

PN 2002831-33

Insight Quick Reference Raven Controllers

(September

2005)

4

of

5

APPLICATION CONFIGURATION (cont.)

Select the desired controller configuration from the list or press the
NEW button if the desired controller is not listed.

Step

3a

Controller Setup – Select Serial Controller from the Device
window and press NEXT.

Step

3b

Select the correct make and model from the lists provided. If
your controller is not listed, the Insight is not compatible on
its current version. Press NEXT when finished.
The Controller name will default to the selected Controller
Make and Model. If you would like to edit the name, press
the KEYBOARD button and type the preferred name and
press the ACCEPT button.

Step

3c

Press the FINISH button to save your Controller Type.

Step

3d

Select the desired Target Rate Increment from the list and
press the NEXT button when finished.

(Models 700, 710, 750,

and 760 will be asked to choose the correct controller channel
before setting the Target Rate Increment.)

Step

3

Step

3e

Models 440, 450, 460, and Sidekick proceed to step 4
Models 660, 700, 710, 750 and 760 set the Operating Mode
to Liquid or Granular. Press NEXT when finished.

Step

4

Select the desired Ground Speed Source. In most cases GPS will be
the primary speed source with Wheel or Radar as the backup. If you
are using a backup ground speed source it is recommended that you
calibrate it before the season begins. Press NEXT. (Ground Speed
calibrations are completed under the CALIBRATE DISTANCE
button on the Application Rate Configuration Screen.)
The Configuration name will default to a name based on your
previous configuration settings. If you would like to edit the name
press the KEYBOARD button and type the preferred name. Press
the ACCEPT button when finished.

Step

5

Press the FINISH button to save your Configuration.

Configuration Settings

Step

6

Additional settings may be necessary for proper operation. Highlight
the desired configuration from the Configuration Window and press
the CONFIGURATION SETTINGS button to adjust these settings.

Many of these settings have already been set through the
wizard. New settings include:
Target Rate Outside Field: (Only pertains to .tgt files)

Set to ZERO if want rate outside field to be zero.
Set to USE LAST if want rate to be the last rate used at the
time the vehicle is detected outside the field. This is useful
when experiencing problems with the vehicle being falsely
detected outside of the field during the outside pass.
Set to TGT DEFAULT if want rate outside field to be the
default rate stored in the target rate file.

Controller Time Delay: Set to 3 seconds.

Step

6a

Press the ACCEPT button when finished.

PRODUCT SETUP

Select the PRODUCT tab in the Application menu to setup your products.

Press the ADD button to begin the Product Setup Wizard.

Step

7a

Select the appropriate Product Type from the list and press
NEXT and proceed to 7b. If Fertilizer is selected, proceed to
7d.

Step

7b

If Planted Seed was selected you will be asked to identify
which crop it belongs to. If any other product type is
selected you will be asked to set the units which will be
logged. Press the NEXT button when finished.

Step

7c

Press the KEYBOARD button to label the product’s
manufacturer (optional) and name (required).
Press the FINISH button to save your Product.

Step

7d

If Fertilizer was selected you will then need to choose the
fertilizer that you will be applying. If the fertilizer that you
are applying is not in the list choose User Defined. Press
NEXT when finished.

Step

7

Step

7e

Press the KEYBOARD button to label the fertilizer’s
manufacturer (optional).
Press the FINISH button to save your product.