background image

PF3000 and PF3000 Pro – Application Rate Mode - Menu Tree for Krohne Flow Meter – March 2002

Revision 2

2 of 3

P.N. 2002831-25

Menu Key

FIELD

LOAD

OPTIONS

SHOW MAP

CAL

SETUP

DIAG

Press Menu Key to switch between Main Menu keys

Settings
Logging device
Logging interval
Log file

[To erase files,
press SHOW
ALL FILES key,
select file, press
FILE OPTIONS
key and press
ERASE FILE
key.]

Settings
Operating mode
Units of Measure
Month/Day/Year
Time
Serial number
Box cal
Voltage cal
GPS check sum
Field marker input
Display brightness

Settings
Controller Make
Controller Model
Product
Units
Ground Speed Source
App Distance From GPS
Full Swath
Tgt Units:Contrler Units
Target Rate Increment
Actual Rate Scale Factor

ADVANCED

SETTINGS

CONTRLER

SETTINGS

[Screen Displays all product/controller
configurations]

EDIT

SETTINGS

CREATE

NEW

DELETE

[Clear data in
loads or erase
all fields
functions]

Selections

MARKS

APP RATE

CONFIG

LOAD

CARD

MEMORY

CONSOLE

MAP

GPS

SETUP

SENSORS

SYSTEM

RAW

NMEA

GPS

DIAG

NMEA MESSAGE
GPS/PORT CONFIGURATION
BEACON DIFFERENTIAL
SATELLITE DIFFERENTIAL
LIGHTBAR
GUIDANCE

AREA

DISTANCE

[Radar calibration screen]

CAL

Guidance Screen Settings
Pattern
Headland Type
Look-Ahead
Display Mode
Swath Direction
Swath Width
Antenna Offset
Pass Skips
Units Displayed
Contour Log Interval

Satellite Differential Screen Settings
Differential source = BEACON or WAAS or SATELLITE
Differential provider
Satellite frequency
Satellite baud rate
Provider user code
Omnistar code
Subscription expiration
Age of differential

Settings
Flowmtr pulses/gal or unit
Act rate:Flowmeter ratio
Area count

Settings
Target rate outside field
Controller time delay
Actual rate units
Log actual rate