6 Troubleshooting

Solution

Problem

Check OA and VSM for status alerts to identify the problem.

See

Chapter 2

on page 11 for LED definitions.

Amber LED on Switch

Verify the power up sequence and allow sufficient time for each compon-
ent to power up. Verify cabling from the switch to the storage enclosures.
For more information about cabling, see “

Cabling the

switch

” on page 17.

Storage not ready during POST
(blade)

nl

OR

nl

Controller lockup during POST

Verify the power up sequence and allow sufficient time for each compon-
ent to power up.

VSM application is not accessible

Verify that the P700m SAS controller is installed in the correct server
mezzanine slot. The switch must be in the correct interconnect bay based
on the mezzanine slot configuration. For more information, see

Chapter

7

, page 33.

Unable to access the storage