beautypg.com

Shared storage—dual controller, standard cabling, Shared, Storage—dual controller, standard cabling – HP 3Gb SAS Switch for HP BladeSystem c-Class User Manual

Page 20

background image

Shared storage—dual controller, standard cabling

This example illustrates standard cabling for a high-availability configuration. In this configuration,
note the following:

Cabling between the two switches and the two controllers in an MSA2000sa controller enclosure.

One cable from each switch to the MSA offers high availability.

Devices and quantities
MSA2012sa controller enclosures: 1
MSA2012sa controllers: 2
BladeSystem c7000 enclosures: 1
3Gb SAS BL switches: 2
Server blade types: half-height and full-height
Connection details

Switch in interconnect bay 5:
• Port 1: to MSA2012sa SAS port A0

Switch in interconnect bay 6:
• Port 1: to MSA2012sa SAS port B0

Notes

If additional ports on the MSA controllers
or 3Gb SAS BL Switch are available, HP
recommends connecting an additional
cable from the switch to the MSA control-
lers, for additional performance and fault
tolerance For an example, see

Shared

storage—dual controller, optimal
cabling

, page 21

Installation procedures

20