Option rom configuration for arrays – HP ProLiant WS460c G6 Workstation-Blade User Manual

Page 59

background image

Software and configuration utilities 59

Mozilla Firefox 2.0 or later

For Linux servers, see the README.TXT file for additional browser and support information.
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant

Servers User Guide on the HP website (

http://www.hp.com/support/SAC_UG_ProLiantServers_en

). To

configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website (

http://www.hp.com/support/CASAC_RG_en

).

Option ROM Configuration for Arrays

Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign
RAID levels, and establish online spare configurations.
The utility also provides support for the following functions:

Reconfiguring one or more logical drives

Viewing the current logical drive configuration

Deleting a logical drive configuration

Setting the controller to be the boot controller

Selecting the boot volume

If you do not use the utility, ORCA will default to the standard configuration.
For more information regarding the default configurations that ORCA uses, see the HP ROM-Based Setup

Utility User Guide on the Documentation CD.
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide
on the HP website (

http://www.hp.com/support/SAC_UG_ProLiantServers_en

). To

configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website (

http://www.hp.com/support/CASAC_RG_en

).

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.

1.

During the server startup sequence, press the F9 key to access RBSU.

2.

Select the System Options menu.

3.

Select Serial Number. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the system during

the manufacturing process and should NOT be modified. This option should only

be used by qualified service personnel. This value should always match the

serial number sticker located on the chassis.

4.

Press the Enter key to clear the warning.

5.

Enter the serial number and press the Enter key.

6.

Select Product ID.

7.

Enter the product ID and press the Enter key.

8.

Press the Esc key to close the menu.

9.

Press the Esc key to exit RBSU.

10.

Press the F10 key to confirm exiting RBSU. The server will automatically reboot.