5 troubleshooting, General troubleshooting instructions, Table 9 general troubleshooting for flex copy xp – HP StorageWorks XP Remote Web Console Software User Manual
Page 47: 9 general troubleshooting for flex copy xp, 5troubleshooting
![background image](/manuals/398526/47/background.png)
47
5
Troubleshooting
If you have a problem with the Command View XP computer or the Command View XP or XP Remote
Web Console software, see the HP StorageWorks Command View XP user guide for XP Disk Arrays or
the HP StorageWorks XP Remote Web Console user guide for XP12000/XP10000/SVS200 for
troubleshooting information.
If you need to call you HP account support representative, see ”
Contacting your HP account support
” on page 48 for instructions.
General troubleshooting instructions
Table 9
General troubleshooting for Flex Copy XP
Error
Corrective action
Pair operation cannot be performed from
Command View XP or XP Remote Web
Console (operation is rejected).
React according to the message.
Pair operation cannot be performed from
RAID Manager XP (operation is rejected).
Check the command’s error message, and react according to the
log file and the HP StorageWorks RAID Manager XP user guide.
Pair operation cannot be performed from
RAID Manager XP (operation is rejected) and
the following error message appears:
An order to the control/command device was
rejected.
The following errors are possible. Examine the actual error, and
look for the corresponding error in the following list. Find the part
code and error number, and contact your HP account support
representative for the recommended response.
Factor
Part
code
Error
number
The Flex Copy XP license is not installed.
0605
8500
The Create Pair operation is rejected because
the licensed capacity was exceeded.
8592
The capacities of the selected P-VOL and
S-VOL are not the same.
8519
The specified copy pair does not consist of an
local array volume and the internal LU to
which an external LU is mapped.
8672
The specified volume’s emulation type is not
OPEN-V.
8673
An I/O operation from the host to the
specified P-VOL or S-VOL is in progress.
8675
Copy processing from the S-VOL to the P-VOL
is rejected because the LUN Security XP
Extension S-VOL Disable mode is set to the
P-VOL.
5821
The LUN Security XP Extension S-VOL Disable
mode is set to the S-VOL.
5821
The specified P-VOL is not implemented.
8549
The specified P-VOL is blockaded.
8550
The specified P-VOL is being formatted.
8551