HP StorageWorks XP Remote Web Console Software User Manual
Page 33
33
• Configuration definition file for S-VOL A:
•
Examples for the Head Office
The following are examples of the configuration definition file that should be prepared in Server B.
Again, you must check the connection configuration using the
raidscan
command first. However,
because P-VOL B is a mapped internal LU by an external LU, you must add the
-fe
option to the
raidscan
command to confirm that the volume is actually in the external array. After checking the
connection configuration, you can create the configuration definition files to operate the Flex Copy XP
pair, which consists of P-VOL B and S-VOL B.
• Checking the connection configuration from Server B:
• Configuration definition file for P-VOL B:
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
127.0.0.1 52051 1000 3000
HORCM_CMD
#dev_name dev_name dev_name
/dev/rdsk/c1t0d2
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
si-pairs dev1 CL1-B 2 1 0
HORCM_INST
#dev_group ip_address service
si-pairs 127.0.0.1 52050
# raidscan -p cl1-c -fe -CLI
PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Status Fence E-Seq# E-LDEV#
CL1-C e4 0 3 1 30053 1 16 SMPL - - 62468 257
# raidscan -p cl1-d -CLI
PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Status Fence P-Seq# P-LDEV#
CL1-D e2 0 4 1 30053 1 17 SMPL - - - -
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
127.0.0.1 52050 1000 3000
HORCM_CMD
#dev_name dev_name dev_name
/dev/rdsk/c1t0d2
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
hicp-pairs dev1 CL1-C 3 1 0
HORCM_INST
#dev_group ip_address service
hicp-pairs 127.0.0.1 52051