beautypg.com

HP Digital Sender Flow 8500 fn1 Document Capture Workstation series User Manual

Page 33

background image

To manually assign an IP address:

1.

At the product control panel, touch the

Administration

button, touch the

Network Settings

option,

touch the

Embedded Jetdirect Menu

option, touch the

TCP/IP

option, touch the

IPV4 Settings

option, and then touch the

Config Method

option.

2.

Touch

Manual

, and then touch

Save

.

3.

On the IPv4 Settings screen, touch

Manual Settings

, and then touch

IP Address

.

4.

Touch the first IP address entry field and use the keyboard to enter the first portion of the IP

address.

5.

Enter the remaining portions of the IP address, and then touch

Save

.

Set up and configure e-mail settings using the E-mail Setup Wizard

Make sure you have a functioning Internet connection before completing this procedure.

1.

At the product control panel, touch the

Administration

button, touch the

Scan/Digital Send Settings

option, touch the

E-mail Settings

option, and then touch

E-mail Setup Wizard

.

NOTE:

You can also use Initial Setup if it is still enabled (touch the

Administration

button, touch

the

Initial Setup

option, and then touch the

E-mail Setup Wizard

option).

2.

Select an SMTP server option, and then follow the onscreen instructions; touch

Next

as you

complete each screen in the wizard.

3.

Touch Finish on the final wizard screen to complete setup and close the wizard.

You can also use the Embedded Web Server (EWS) to set up the address book with LDAP (Lightweight

Directory Access Protocol).

1.

Click the Security tab, click Access Control, and then click the Setup link for LDAP.

2.

Follow the onscreen instructions to set up and configure LDAP.

NOTE:

You must select the Enable LDAP Sign In checkbox (under Setup) to enable this sign-

in method.

3.

When configuration is complete, click OK.

Manually configure IPv4 TCP/IP parameters from the control panel

In addition to using the Embedded Web Server, you can also use the control-panel menus to set an IPv4

address, subnet mask, and default gateway.

1.

At the product control panel, touch the

Administration

button, touch the

Network Settings

menu,

touch the

Embedded Jetdirect Menu

option, touch the

TCP/IP

option, touch the

IPV4 Settings

option, and then touch the

Config Method

option.

2.

Touch

Manual

, and then touch

Save

.

3.

Touch the Back button to return to the IPv4 Settings screen.

4.

On the IPv4 Settings screen, touch

Manual Settings

, and then touch the option you wish to

manually set and follow the onscreen instructions to change the option setting.

5.

Touch the Back button repeatedly until you return to the

Embedded Jetdirect Menu

.

ENWW

Basic configuration using the Administration menu

25