beautypg.com

Gpu/coprocessor enablement options, Large bar setting for coprocessor installation – HP ProLiant SL270s Gen8 SE Server User Manual

Page 45

background image

Hardware options installation 45

c.

To prevent interference with the DIMMs and heatsink, bend the Mini-SAS Y-cable upwards, and then

tuck it underneath the drive cage.

13.

Install the GPU cage (on page

23

)

14.

Install the shipping brackets and shipping plates (on page

19

).

GPU/coprocessor enablement options

Large BAR setting for coprocessor installation

Coprocessor model Number of coprocessor

supported

Switch position 9
setting

Intel Xeon Phi 5110P 1 - 8

On = Enabled

Intel Xeon Phi 7120P 1 - 6

On = Enabled

The system board embedded HP Dynamic Smart Array B320i Controller does not support large BAR function.

When the large BAR function is enabled, drive connection to the system board SATA/Mini-SAS connectors is not
supported. Connect installed drives to a storage controller board.