Installing the fbwc module and capacitor pack – HP ProLiant SL270s Gen8 SE Server User Manual
Page 37

Hardware options installation 37
IMPORTANT:
The battery pack might have a low charge when installed. In this case, a POST
error message is displayed when the server is powered up, indicating that the battery pack is
temporarily disabled. No action is necessary on your part. The internal circuitry automatically
recharges the batteries and enables the battery pack. This process might take up to four hours.
During this time, the cache module functions properly, but without the performance advantage of
the battery pack.
NOTE:
The data protection and the time limit also apply if a power outage occurs. When power
is restored to the system, an initialization process writes the preserved data to the hard drives.
Installing the FBWC module and capacitor pack
CAUTION:
In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
1.
Power down the server (on page
2.
Disconnect all peripheral cables from the server.
3.
Remove the server from the chassis (on page
4.
Remove the shipping brackets and shipping plates (on page
5.
Remove the SFF hot-plug drive cage ("
Remove the hot-plug SFF drive cage
" on page
6.
7.
If using a storage controller, remove the PCI riser cage ("
Remove the PCI/FlexibleLOM riser cage
" on
8.
Connect the capacitor pack cable to the cache module.
9.
Do one of the following: