Figure 13 change wwn and pfc name dialog box, Grouping host bus adapters, Adding multiple hbas to a pfc group – HP StorageWorks XP Remote Web Console Software User Manual
Page 25: 13 change wwn and pfc name dialog box
Performance Control XP user guide
25
The following is the procedure for changing an existing PFC name. For details about assigning PFC names,
see ”
Measuring traffic between host bus adapters and ports for many-to-many connections
1.
Start Performance Control XP (”
Starting Performance Control XP
” on page 18). The Performance
Control pane appears.
2.
Click WWN.
3.
In the upper-left tree view, click a host bus adapter (
) from below the Monitor branch, and
right-click the selection.
4.
Select Change WWN & PFC Name. The Change WWN and PFC Name dialog box appears.
Figure 13
Change WWN and PFC Name dialog box
5.
Enter a new PFC name (up to eight characters) in the PFC Name box, and click OK.
6.
In the Performance Control pane, click Apply. The settings in the pane are applied to the disk array.
Replacing host bus adapters (many-to-many connections only)
If a host bus adapter fails, replace the adapter with a new one. After you finish the replacement, delete the
old host bus adapter from the Performance Control pane, and register the new host bus adapter.
Use the following procedure to quickly and easily remove the old adapter and register a new one.
1.
Start Performance Control XP (”
Starting Performance Control XP
” on page 18). The Performance
Control pane appears.
2.
Click WWN.
3.
In the upper-left tree view, click the old host bus adapter (
) below the Monitor branch, and
right-click the selection.
4.
Select Change WWN & PFC Name. The Change WWN and PFC Name dialog box appears
5.
Enter the WWN of the new host bus adapter in the WWN box.
6.
If necessary, enter a new PFC name (up to eight characters) in the PFC Name box.
7.
Click OK.
8.
In the Performance Control pane, click Apply. The settings in the pane are applied to the disk array.
Grouping host bus adapters
Use Performance Control XP to create a PFC group that contain multiple host bus adapters. All host bus
adapters (HBAs) in one PFC group must be of the same priority. Prioritized WWNs (for example,
high-priority HBAs) and non-prioritized WWNs (for example, low-priority HBAs) cannot be mixed in one
PFC group.
You can use a PFC group to switch the priority of multiple HBAs from prioritized to non-prioritized, or vice
versa. You can also use a PFC group to set the same upper limit value to all HBAs in the group.
Adding multiple HBAs to a PFC group
1.
Start Performance Control XP (”
Starting Performance Control XP
” on page 18). The Performance
Control pane appears.
2.
Click WWN.
3.
In the lower-left tree view, right-click the Subsystem folder.