HP ProLiant ML350e Gen8 v2-Server User Manual
Page 72

Hardware options installation 72
15.
Install hot-plug drives.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
Populate drive bays based on the drive numbering sequence. Start from the drive bay with the lowest
device number. For device numbering information see "SAS and SATA device numbers (on page
)."
16.
Install the fan modules and the fan blank (on page
17.
Install any full-length PCI expansion cards that were removed ("
" on page
18.
Install the system air baffle (on page
19.
If removed, install the PCI air baffle ("
" on page
20.
Install the access panel (on page
21.
Return the server to an upright position.
22.
Install the front bezel (on page
23.
Connect each power cord to the server.
24.
Connect each power cord to the power source.
25.
Redundant hot-plug power supply enablement kit
option
To install the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Unlock the front bezel (on page
4.
Place the server on its side.