beautypg.com

HP Insight Management Agents User Manual

Page 99

background image

Firmware Revision displays the firmware revision of the drive enclosure or box. Use this
information for identification purposes.

Serial Number displays the serial number of the drive enclosure or box. Use this information
for identification purposes.

Drive Bays displays the number of drive bays provided by this storage system. If duplexing
hardware is used with the storage system, the drive bay number is less than the number of
physical drive bays in the enclosure.

Fan Status displays the status of the fan subsystem in the drive enclosure, or box. The following
values are possible:

OK - The fan subsystem is working properly.

Failed - A fan has failed and there are not enough fans in the fan subsystem to keep the
enclosure cool. Check your fan subsystem as soon as possible. Continued operation may
cause failure of the drives.

Degraded - A fan has failed but there are still enough fans in the fan subsystem to keep
the enclosure cool.

Unknown - The Storage Agents do not recognize the status of the fan subsystem. You may
need to upgrade your software.

No Fan - This storage system does not have a fan.

Power Supply Status displays the status of the redundant power supply. The following values
are possible:

OK - All component power supplies that make up the redundant power supply are in
normal working order.

Degraded - One of the component power supplies that make up the redundant power
supply has failed. The drive system (either a drive subsystem or a power supply for the
main unit) continues to operate. However, if the remaining power supply should fail, the
drive system will lose all power and data loss could occur. To correct this situation,
schedule a time to bring the device down and replace the failed power supply.

Unknown - The Storage Agents do not recognize the redundant power supply. You may
need to upgrade your software.

No Redundant Power Supply - This storage system does not support a redundant power
supply.

Thermal Status displays the temperature status of the drive system. The following values are
possible:

OK - The temperature is within normal operating range.

Degraded - The temperature is outside of normal operating range. Make sure the cover
is on the storage system.

Failed - The temperature is outside of normal operating range, and could permanently
damage the system. Ensure that the fans are spinning and check the room temperature.

Unknown - The Storage Agents do not recognize the thermal status. You may need to
upgrade your software.

No Temperature Monitoring - This storage system does not support temperature monitoring.

If the storage system uses Target Based Management (TBM), the following information with
regards to the storage box management will be displayed.

Initiator SAS Address displays the SAS address of the initiator connected to the drive box.

Target SAS Address displays the SAS address of the target (i.e. the drive box itself).

Storage Agent

99