Sub-system Classification

Power Subsystem

This section displays information about the redundant power supplies. The following entries may
be displayed:

Location—Displays the bay where the power supply is located.

Condition—Displays the status of the power supply. The following values are possible:

OK—A power supply is installed and operating normally.

Failed—A power supply is installed and is no longer operating. Replace the power supply.

Not Installed—Nothing is installed in this power supply bay.

Unknown—The Server Agent is unable to determine if this storage system power supply
bay is occupied.

Serial Number—Displays the serial number of the power supply. This information can be used
for identification purposes.

Firmware Revision—Displays the firmware revision of the power supply.

Present—Represents whether the power supply is present in the chassis.

Status—Represents the status of the power supply in the chassis. The following values are
possible:

No Error

General Failure

Bist Failure

Fan Failure

Temperature Failure

Interlock Open

EPROM Failed

VREF Failed

DAC Failed

RAM Test Failed

Voltage Channel Failed

Orring Diode Failed

Brownout

Give Up On Startup

NVRAM Invalid

Calibration Table Invalid

If the power supply is absent, the status is "Not Applicable"

Used Capacity (%)—Represents the current power supply capacity which is a percentage of
its maximum capacity.

Used Capacity (W)—Represents the current power supply capacity in watts.