beautypg.com

Modifying connection names – HP StorageWorks 1500cs Modular Smart Array User Manual

Page 50

background image

Using the Command Line Interface 50

=> ctrl ch="Lab 4" show ssp

A typical screen response could be:

MSA1000 at Lab 4

Adapter ID: 210000E08B07A68F

connectionname: Unknown

Location: Local

Status: Online

Host Mode: Default

Adapter ID: 5034414235583942

connectionname: Unknown

Location: Unknown

Status: Offline

Host Mode: Default

Now activate SSP, and then show the logical drives that are present so that you can determine which
drive to unmask:

=> ctrl ch="Lab 4" modify ssp=on forced

=> ctrl ch="Lab 4" ld all show

MSA1000 at Lab 4

array A

logicaldrive 1 (33.9 GB, RAID 0, OK)

array B

logicaldrive 2 (298 MB, RAID 1+0, OK)

logicaldrive 3 (896 MB, RAID 1+0, OK)

Finally, unmask an adapter ID and then check the SSP status:

=> ctrl ch="Lab 4" ld 1 modify unmask 210000E08B07A68F

=> ctrl ch="Lab 4" show ssp

MSA1000 at Lab 4

Adapter ID: 210000E08B07A68F

connectionname: Unknown

Location: Local

Status: Online

Host Mode: Default

logicaldrive 1 is unmasked

Adapter ID: 5034414235583942

connectionname: Unknown

Location: Unknown

Status: Offline

Host Mode: Default

logicaldrive 1 is masked

Modifying connection names

You can convert a lengthy adapter ID into a brief connection name that can be used in all future
commands.