beautypg.com

Sample custom input script – HP StorageWorks 1500cs Modular Smart Array User Manual

Page 32

background image

Scripting in ACU 32

If you do not specify a capture file name, ACU gives the file the default name of ACUCAPT.INI and
places it in the ACU working directory.

In Input mode:

cpqacuxe -i FILENAME

If you do not specify an input file name, ACU gives the file the default name ACUINPUT.INI and places it
in the ACU working directory.

If any errors occur during either process, these errors are noted in the file ERROR.INI that is logged to the
default working directory.

Sample custom input script

The following script gives all possible values for each option.

If an option is shown in bold type, you must enter a value for that option.

If a value is shown in bold type, ACU uses that value as a default setting when creating new logical
drives.

An asterisk next to a line denotes that the line is not used in Automatic mode.

You can use this script as a template for your own script.

Action

= Configure|Reconfigure

Method = Custom|Auto

Controller

= All | Slot [N] | WWN [N] | SerialNumber [N] | IOCabinet

[N],IOBay [N],IOChassis [N],Slot [N],Cabinet [N],Cell [N]

ClearConfigurationWithDataLoss = Yes|No

LicenseKey = XXXXX-XXXXX-XXXXX-XXXXX-XXXXX

DeleteLicenseKey = XXXXX-XXXXX-XXXXX-XXXXX-XXXXX

ChassisName = “XXXXXXXXXXXXXXXXXXXX”

ReadCache = 0|10|20|25|30|40|50|60|70|75|80|90|100

WriteCache = 0|10|20|25|30|40|50|60|70|75|80|90|100

RebuildPriority = Low|Medium|High

ExpandPriority = Low|Medium|High

SurfaceScanDelay = N

* SSPState = Enable|Disable

PreferredPathMode = Auto|Manual

* Array

= A|B|C|D|E|F|G|...Z|a|b|c|d|e|f

OnlineSpare = Port:ID,Port:ID... | Box:Bay,Box:Bay... |

Port:Box:Bay,Port:Box:Bay,... | None

* Drive = Port:ID,Port:ID... | Box:Bay,Box:Bay... |

Port:Box:Bay,Port:Box:Bay,...

* LogicalDrive

= 1|2|3|...32

RAID = 0|1|5|6|adg

* Size = [N]|Max

* Sectors = 32|63

* StripeSize = 8|16|32|64|128|256