Using the Command Line Interface 47

Creating a logical drive

When you use the CLI to create a logical drive, the array that holds the logical drive is created implicitly.
(The CLI is different from the GUI in this respect, because in the GUI you must create the array explicitly in
a separate step.)

Syntax:

create type=ld [parameter=value]

To create a logical drive on a new array, specify both the controller and the drives that are to
constitute the new array. You can specify each drive individually, or you can specify a drive range.
For example:

ctrl slot=5 create type=ld drives=1:0,1:1,1:3 raid=adg

or

ctrl slot=5 create type=ld drives=1:1-1:3 raid=adg

To create a logical drive on an existing array, specify the array. You do not need to specify the
drives in this case because they are already defined. For example:

ctrl slot=5 array A create type=ld size=330 raid=adg

Standard parameters for creating a logical drive are described in the following table. If you do not
specify a particular parameter when creating a logical drive, the CLI uses the default value for that
parameter.

Parameter Acceptable

values

Comments

drives

[#:]#:#,[#:]#:#,[#:]#:#–

[#:]#:#,...|all|allunassigned

The default setting is

all.

raid

6|adg|5|1+0|1|0|?

The default setting is the highest
level that the logical drive can
accept.

ss

8|16|32|64|128|256|default|?

Units are KB.*
The default setting depends on the
RAID level.

size

#|max|?

This parameter determines the
desired size of the logical drive.
Units are MB.*
The default setting is

max.

sectors

32|63|default|?

The default setting depends on the
operating system.

aa

enable|disable

The default setting is

enable.

drivetype

sas|satalogical|sata|saslogical|paral

lelscsi

*Use only these units. Do not enter any extra text in the command to specify the units.

Sample scenario

Consider a situation in which you want to create two arrays. One of these arrays needs two logical
drives, while the other needs only one.

First, determine what physical drives are available and what their properties are:

=> ctrl ch="Lab 4" pd all show

For this sample scenario, the screen response is:

MSA1000 at Lab 4

unassigned

physicaldrive 1:12 (box 1:bay12, Parallel SCSI, 36.4 GB, OK)

This manual is related to the following products: