Hostmode, Error reporting, Acu scripting error messages – HP StorageWorks 1500cs Modular Smart Array User Manual
Page 40
Scripting in ACU 40
HostMode
This option specifies the HostMode for a selected HBA. Setting the Host Mode optimizes the storage array
for the selected operating system. The available host modes for an HBA are device-specific. Not all modes
are available on all devices. Not all HBAs support a HostMode.
The following operating system options might be available:
•
Default
•
Microsoft® Windows®
•
OpenVMS
•
Tru64
•
Linux
•
Solaris
•
Netware
•
HP-UX
Error reporting
Any errors that are encountered during ACU scripting are logged to ERROR.INI. This error file describes
the error and if possible indicates the controller, array, and logical drive that are associated with the
error.
The error reporting in ACU scripting is not as specific as the error reporting in the ACU GUI. Instead, it is
designed to give an advanced user enough information to understand what went wrong so that they can
correct the problem and continue. Some of the possible error messages are listed in the table ("
ACU scripting error messages
Message
Comment or explanation (if not self-explanatory)
(text) is not a controller command.
—
(text) is not a logical drive
command.
—
(text) is not a supported command.
—
(text) is not an array command.
—
(text) command expected.
The specified command is missing or in the incorrect place in the
file.
Array not specified.
Some commands in the script require an array, but no array is
specified in the script file.
Array requires an odd number of
drives.
This error message occurs if you attempt to add an odd number of
drives to an existing array that has RAID 1 logical drives, and the
controller does not support RAID-level migration.
Cannot change array spare.
The current configuration does not allow the number of spares in the
array to be changed.
Cannot change logical drive array
accelerator setting.
The current controller configuration does not allow the array
accelerator setting to be changed.
Cannot change logical drive
sectors.
You cannot change the MaxBoot setting on a configured logical
drive because doing so causes data loss.
Cannot change SSP settings.
—