beautypg.com

Handling automatic pre-failure events – HP Insight Control Software for Linux User Manual

Page 26

background image

5.

Select the servers that have access to the same LUNs on shared storage from the Available Items box
and move them to Selected Items box.

6.

Click Save as Collection to save the collection with an appropriate name, for example, Prefailure
VMware ESX Collection.

Handling pre-failure events is supported for virtual machines that are on shared storage.

Handling automatic pre-failure events

To handle automatic pre-failure events, perform the following:

1.

Click Deploy

Virtual MachineHandle Virtual Machine Host Prefailure Events.

2.

In Step 1, Select the target events, select the PreFailure Events collection that has been created, then
click Apply.

3.

Click Add System Filters….

4.

Select the Collection under Add filters by selecting from:.

5.

Select the system collection that has been created as described in Prerequisites.

6.

Click Apply, then Next. The Confirm Details screen appears.

7.

To have the events automatically handled, click Schedule. The GUI for Step 2: Schedule Taskappears.
Set the schedule as needed. Click Done, when the event that meets the criteria on the failed host occurs,
and the virtual machines are recovered to an alternate host or to place the host on maintenance mode.

Handling automatic pre-failure events using the vCenter Server DRS cluster enabled
in the vCenter Server

Prerequisite: The ESX hosts must be in a cluster in VMware vCenter Server and DRS must be enabled on the
cluster.

To handle automatic pre-failure events using the vCenter Server DRS cluster enabled in the vCenter Server,
perform the following:

Create a collection in Systems Insight Manager containing the ESX hosts that are in the DRS enabled
cluster in vCenter.

Configure pre-failure handling using the steps mentioned in

Handling automatic pre-failure events

.

When the pre-failure events are generated on any system in the System Collection - Prefailure VMware
ESX Collection

, the VMware ESX host is placed in maintenance mode in VMware vCenter Server. VMware

vCenter Server then moves all the virtual machines hosted on this VMware ESX system onto other hosts
available in the VMware Cluster.

Handling semi-automatic pre-failure events with the vCenter Server DRS cluster enabled
in the vCenter Server

In the semi-automatic mode of event handling, verify the SMTP settings in the Options

EventsAutomatic

Event Handling

Email Settings. When a pre-failure event occurs, you are notified through email. When

you receive the email, perform the following steps to handle the pre-failure events:

1.

Select Deploy

Virtual MachineHandle Virtual Machine Host Prefailure Events.

2.

In the Step 1, Select the target events page, select the PreFailure Events collection that has been
created. Click Apply.

3.

Click Add System Filters….

4.

Select the Collection under Add filters by selecting from:.

5.

Select the system collection that has been created. Perform the steps to create a collection as described
in

Prerequisites

.

6.

Click Apply, then click Next. The Step 2: Confirm Details Pagescreen appears.

7.

Click Run Now.

The virtual machines are recovered successfully on to the target host and the source host is placed in
maintenance mode.

26

Managing virtual machines