NonStop AutoTMF Commands

HP NonStop AutoTMF Software User’s Guide429952-016

6-96

STATUS

Activities that are logged include:

Starting and stopping the log.

Any errors obtaining configuration information from MapDB.

Monitor opens and closes by requesting processes.

The result of ATMFFILESET and ATMFPROGRAM configuration requests.

Any mismatch between an AutoTMF runtime library and the monitor or MapDB.

Fault tolerance process events, such as a backup process takeover.

Local CPU failures and reloads.

Remote network status changes

STATUS

Displays information about various objects.

PROCESS

displays information about the monitor process.

LOG

requests information about the monitor log file, if any.

LICENSE

displays information about the AutoTMF license for the current system.

SECURITY

Instructs the monitor to accept further commands only from a specific set of process
access ids.

N | C | U | A | G | O | -

the Guardian security specifier. The user issuing the command must match the
monitor process access id at the specified security level.

Note. Information in the activity log is for informational and diagnostic purpose. It is not
intended to be an official or reliable record for continuing management or control purposes.
The content and format of the log is subject to change without notification.

MONITOR STATUS { PROCESS | LOG | LICENSE }

MONITOR SECURITY { N | C | U | A | G | O | - }