beautypg.com

Storage tab: user-defined application properties – HP X1000 Network Storage Systems User Manual

Page 57

background image

Storage tab—Displays the user-defined application's storage space, including allocated space,
used space, free space, and the following storage allocation details:

Table 21 Storage tab: User-defined application properties

Value

Property

Path to the file directory on the application server where the user-defined
application data is saved by the user-defined application. The file dir-
ectory is located on the volume created on the iSCSI LUN that was ex-
ported by ASM to the application server.

Application Path

Communication protocol used to transfer data between the server that
hosts the user-defined application and your HP Storage System.

Protocol

Name of server that hosts the user-defined application.

Application Server Host Name

Name of the volume on the application server to which the user-defined
application saves its data. The volume resides on the iSCSI LUN (logical
disk) exported by ASM to the application server.

Application Server Volume -
Name

Status of the volume on the application server where the user-defined
application data is stored.

Application Server Volume -
Status

Indicates if user-defined application storage is configured with exclusive
storage. See

Table 5

on page 23 for more information.

Application Server Volume - Ex-
clusive Storage

The RAID level to which the user-defined application storage is con-
figured. See

Customizing RAID levels

on page 25 for more information.

Application Server Volume - RAID
Level

The RAID stripe size to which the user-defined application storage is
configured. See

Table 5

on page 23 for more information.

Application Server Volume - RAID
Stripe Size

Speeds up reads when enabled. This setting is determined by the stor-
age array, not ASM.

Application Server Volume - Read
Cache

Speeds up writes when enabled. This setting is determined by the stor-
age array, not ASM.

Application Server Volume -
Write Cache

The number of hot spares with which the database component storage
is configured. See

Table 5

on page 23 for more information.

Application Server Volume -
Number of Hot Spares

Path the application server volume is mounted on. The volume is built
on the iSCSI LUN exported by ASM to the application server.

Application Server Volume -
Mount Paths

Warning Threshold tab—Allows you to change the percent full warning threshold value for the
user-defined application. See

Setting a percent full warning threshold

on page 26 for more inform-

ation.

Snapshots tab — Allows you to schedule snapshots of the user-defined application. For more in-
formation, see “

Scheduling and running snapshots

” on page 33.

Backup tab — Allows you to schedule backups of the user-defined application. See

Scheduling backups

” on page 36 for more information.

Replication tab — Allows you to configure data replication of the user-defined application. See

Running replication

” on page 40 for more information.

HP StorageWorks X1000 Automated Storage Manager