Chapter Five - SCSI Bridge Electronics

Note: Because the beginning of tape is written to every time a tape is unloaded, this area of
the tape tends to wear sooner than the rest of the tape media's length. As a result, it is not
unusual to experience rewrites or ECCs at the beginning of tape. If these situations occur, the
predetermined thresholds can be exceeded early, but the percentage then drops below the
threshold as reading or writing moves further down the tape. To signal this, the error-alert LED
blinks when the error rates currently exceed the set values. It returns to a steady illumination
if, once exceeded, the error rate falls below the set value.

Rwr% 0.5
Ecc:80.5

PRESS to
Alter

Rwr% 0.5
Ecc:80.5

PRESS to
Incremnt

Rwr% 0.5

Ecc:80.5
PRESS to
Incremnt

Rwr%30.5

Ecc:80.5
PRESS to
Incremnt

Rwr%30.7
Ecc:80.5

PRESS to
Alter

Rwr%30.7
Ecc:20.5

PRESS to
Incremnt

Rwr%30.7

Ecc:24.5
PRESS to
Incremnt

Rwr%30.7
Ecc:24.2
PRESS to
Incremnt

Rwr%30.7
Ecc:24.2
PRESS if
Done

Figure 33

Setting error-alert (ECC/Rewrite percentages) thresholds


5.12 Setup 2 Configuration Display Format Items

Enter
Set-Up 2

PRESS to
Select

Key:2.01

[288FEA]

*NOT sel
ectable*

Options:
00001401

PRESS to

Alter

BaudRate
9600 bps

PRESS to

Alter

EM: ----
NONE

*NOT sel
ectable*

Exit
Set-Up 2

PRESS to
Select


Figure 34

Setup 2 configuration items


5.12.1 Editing option access key

This is factory-configured and is not selectable.

Key:7.0E

[288FEA]
*NOT sel
ectable*


Figure 35

Option access key


HP StorageWorks DAT 72 (Model 5242-2SE) User's Guide

23

HP Part Number 528297-003 July 2005

This manual is related to the following products: