Chapter five - scsi bridge electronics, 11 setup 1 configuration display format items – HP NonStop G-Series User Manual
Page 25
Chapter Five - SCSI Bridge Electronics
5.11 Setup 1 Configuration Display Format Items
Enter
Set-Up 1
PRESS to
Select
SCSI ID:
[00]
PRESS to
Alter
Tape ID:
[00]
*NOT sel
ectable*
Tape
Term: On
*NOT sel
ectable*
Density:
[C0]
PRESS to
Alter
Rwr% 0.5
Ecc: 0.5
PRESS to
Alter
Exit
Set-Up 1
PRESS to
Select
Figure 28
Setup 1 configuration items
5.11.1 Setting the unit SCSI ID
SCSI ID:
[00]
PRESS to
Alter
SCSI ID:
[01]
PRESS if
Done
SCSI ID:
[01]
PRESS to
Incremnt
Figure 29
Setting the unit SCSI ID
This configuration menu item sets the host SCSI ID the NonStop server uses to select the
5242-2SE. Values of 0 through 7 can be entered using the Numeric Entry m
ethod
(ID=7 is
reserved for the NonStop server. ID=5 is used for a single drive on a SCSI bus. If 2 drives are
daisy chained, the second drive uses ID=4). No two devices can have the same SCSI ID.
Note:
The ability to independently set the tape drive's SCSI ID and the NonStop server
SCSI ID is useful. As you add devices to a system's SCSI bus, you do not have to
manipulate jumpers or switches on the tape drive. The tape drives ID can be altered
from the tape drives front panel without regard to the actual physical SCSI ID of the
drive itself, making SCSI device additions quick and simple.
5.11.2 Setting the Tape Drive ID
This is factory-configured and is not selectable.
Tape ID:
[00]
*NOT sel
ectable*
Figure 30
Tape drive ID
HP StorageWorks DAT 72 (Model 5242-2SE) User's Guide
21
HP Part Number 528297-003 July 2005
5.11.3 Setting the Tape Termination